Products > Automation PCs > Supercapacitor UPS > NP-6130 Series > NP-6310-A NP-6310-A | Book Style Capacitor UPS The UPS module that can protect your PC and data in case of power loss Features Secure Shutdown & Reboot function for IPC systemsWide voltage input: 12V/24V adaptiveBackup mode power output: 12V/24V (depending on the"> Products > Automation PCs > Supercapacitor UPS > NP-6130 Series > NP-6310-A NP-6310-A | Book Style Capacitor UPS The UPS module that can protect your PC and data in case of power loss Features Secure Shutdown & Reboot function for IPC systemsWide voltage input: 12V/24V adaptiveBackup mode power output: 12V/24V (depending on the">
X

Contact Info

  • Nodka Europe Luchthavenweg 81 Room 038 5657 EA Eindhoven The Netherlands Email: [email protected]
  • Nodka Europe Luchthavenweg 81 Room 038 5657 EA Eindhoven The Netherlands Email: [email protected]

NP-6310-A | Book Style Capacitor UPS

The UPS module that can protect your PC and data in case of power loss
  • Secure Shutdown & Reboot function for IPC systems
  • Wide voltage input: 12V/24V adaptive
  • Backup mode power output: 12V/24V (depending on the input voltage)
  • The powered device (PC) can monitor the status in real time via RS-232/USB
  • Long backup time, the powered device (PC) automatically shuts down safely
  • Battery with high cycle stability (500,000 charging and discharging cycles)
  • Long life cycle: 10+ years
  • Wide operating temperature: -20 ~ 60°C

Supercapacitor UPS Product Information

DC_IN
Voltage DC12V / DC24V
Current 12A
Protection Overvoltage and power anti-reverse connection protection EFT ±1500V, electrical surge DC2000V
DC_OUT
Voltage 12V / 24V
Current 9A
Protection Overcurrent
Electrical parameters
Power In Idle 3W
Maximum Power 60W/12V, 120W/24V
Max. Charging current 3A
Supercapacitor
Capacitance 1080 Ws
Active life The charge and discharge times are up to 500000
Signal type
Power DI/DO dc-dc isolated power VCC DC24V 40mA
DC OK Relay Normal Open output
Bat.Mode NPN output
Bat.Ready NPN output
SW NPN output
Remote NPN input
Bat.Start NPN input
Dev.Psts NPN input
Data interface
Interface DB9
Mode RS232 / RS485
Protocol Modbus RTU
Parameters Can be set via register 40003 default baud rate 115200bps, 8-bit data bit, 1-bit stop bit, no parity
Modbus slave address The address can be set via register 40004, default is 1
Physical
Dimensions 180.0(mm) × 43.0(mm) × 125.2(mm)
Weight 850(g)
Mounting
Mount Wall-Mounted or Din-Rail
Power
Input Voltage DC12V/24V
Environment
Work temperature -20ºC ~ 60ºC (-4℉~140℉) with air flow (mSATA)
Storage Temperature -40ºC ~ 80ºC (-40 ~ 176℉) with air flow (msATA)
Relative Humidity 5~95% (Non-condensing)
Click below to download Datasheet