Products > Automation PCs > Supercapacitor UPS > NP-6130 Series > NP-6310-A NP-6310-A | Book Style Capacitor UPS The UPS module that can protect your PC and data in case of power loss Features Secure Shutdown & Reboot function for IPC systemsWide voltage input: 12V/24V adaptiveBackup mode power output: 12V/24V (depending on the"> Products > Automation PCs > Supercapacitor UPS > NP-6130 Series > NP-6310-A NP-6310-A | Book Style Capacitor UPS The UPS module that can protect your PC and data in case of power loss Features Secure Shutdown & Reboot function for IPC systemsWide voltage input: 12V/24V adaptiveBackup mode power output: 12V/24V (depending on the">
DC_IN | |
---|---|
Voltage | DC12V / DC24V |
Current | 12A |
Protection | Overvoltage and power anti-reverse connection protection EFT ±1500V, electrical surge DC2000V |
DC_OUT | |
Voltage | 12V / 24V |
Current | 9A |
Protection | Overcurrent |
Electrical parameters | |
Power In Idle | 3W |
Maximum Power | 60W/12V, 120W/24V |
Max. Charging current | 3A |
Supercapacitor | |
Capacitance | 1080 Ws |
Active life | The charge and discharge times are up to 500000 |
Signal type | |
Power | DI/DO dc-dc isolated power VCC DC24V 40mA |
DC OK | Relay Normal Open output |
Bat.Mode | NPN output |
Bat.Ready | NPN output |
SW | NPN output |
Remote | NPN input |
Bat.Start | NPN input |
Dev.Psts | NPN input |
Data interface | |
Interface | DB9 |
Mode | RS232 / RS485 |
Protocol | Modbus RTU |
Parameters | Can be set via register 40003 default baud rate 115200bps, 8-bit data bit, 1-bit stop bit, no parity |
Modbus slave address | The address can be set via register 40004, default is 1 |
Physical | |
Dimensions | 180.0(mm) × 43.0(mm) × 125.2(mm) |
Weight | 850(g) |
Mounting | |
Mount | Wall-Mounted or Din-Rail |
Power | |
Input Voltage | DC12V/24V |
Environment | |
Work temperature | -20ºC ~ 60ºC (-4℉~140℉) with air flow (mSATA) |
Storage Temperature | -40ºC ~ 80ºC (-40 ~ 176℉) with air flow (msATA) |
Relative Humidity | 5~95% (Non-condensing) |